Data Acquisition & Logger

img cate
HOBO RX3000 Remote

Rayastock

Rp 14.324.434 Rp 17.905.543

The HOBO RX3000 adalah stasiun logging Onset generasi berikutnya data remote yang menyediakan akses cepat ke data lingkungan spesifik di mana saja, kapan saja melalui

HOBO 4-Channel Analog

Rayastock

Rp 3.340.091 Rp 4.175.114

HOBO UX120-006M Analog Data Logger adalah kinerja tinggi, layar LCD data logger untuk membangun aplikasi monitoring kinerja. Sebagai Onset tertinggi akurasi data logger, ia

100 Amp Accu-CT

Rayastock

Rp 3.783.582

Transformator arus Accu-CT split-inti menawarkan akurasi yang luar biasa dan operasi satu

20 AMP Mini Split-inti

Rayastock

Rp 3.366.705

ukuran 20 AMP split-inti AC Current Transformer (CT) dipasang di sekitar kawat berarus untuk mengukur ampere AC. CT ini menyediakan 0-,333 Volt AC

250 Amp Accu-CT

Rayastock

Rp 3.783.582

Transformator arus Accu-CT split-inti menawarkan akurasi yang luar biasa dan operasi satu

20 Amp Accu-CT

Rayastock

Rp 3.783.582

Transformator arus Accu-CT split-inti menawarkan akurasi yang luar biasa dan operasi satu

HOBO Plug Beban Data

Rayastock

Rp 5.579.264

HOBO Plug Beban Data Logger memiliki akurasi tinggi, mudah menyebarkan data yang logger yang mengukur dan mencatat kekuatan dan energi konsumsi beban 120V steker dari peralatan

50 Amp Accu-CT

Rayastock

Rp 3.783.582

Transformator arus Accu-CT split-inti menawarkan akurasi yang luar biasa dan operasi satu

HOBO 4-Channel Analog

Rayastock

Rp 4.175.114

HOBO UX120-006M Analog Data Logger adalah kinerja tinggi, layar LCD data logger untuk membangun aplikasi monitoring kinerja. Sebagai Onset tertinggi akurasi data logger, ia

HOBO 4-Channel Eksternal

Rayastock

Rp 10.097.421

Mempekerjakan beberapa energi dan sensor lingkungan, mulai dari ampli ke suhu , dengan data logger HOBO U12-008. Kandang cuaca yang memungkinkan U12-008

HOBO

Rayastock

Rp 4.146.460

Ukur suhu , kelembaban relatif , cahaya intensitas, dan banyak lagi dengan HOBO U12-012. Dengan pengukuran resolusi

HOBO H22 Energi Data

Rayastock

Rp 7.553.109

Memonitor energi dan peralatan industri dengan data 15-saluran ini logger (Bagian # H22-001). Dengan beberapa saluran, energi dan fasilitas manajer dapat dengan cepat dan

HOBO Suhu / Kelembaban

Rayastock

Rp 12.320.760

HOBO ® ZW-007 adalah mudah-ke-menyebarkan, 4-channel wireless data node. Ini mencakup 2m eksternal suhu /

HOBO Empat Eksternal

Rayastock

Rp 9.875.087

HOBO ® ZW-008 adalah 4-channel wireless data node menampilkan dua port analog dan dua port masukan pulsa. Ini secara nirkabel

HOBO Empat Analog

Rayastock

Rp 9.875.087

HOBO ® ZW-006 adalah 4-channel wireless data node dengan empat port analog. Ini secara nirkabel mentransmisikan data secara

HOBO Empat-Channel data

Rayastock

Call

HOBO ® ZW-005 adalah mudah-ke-menyebarkan, 4-channel wireless suhu / kelembaban relatif data

HOBO U30 USB Weather

Rayastock

Rp 9.262.760

stasiun cuaca yang paling tahan lama di luar ruangan solusi pemantauan lingkungan Onset ini. Pengguna dapat dengan mudah mengkonfigurasi U30-NRC Weather Station

4 sampai 20 mA

Rayastock

Rp 1.478.655

Kabel untuk menghubungkan sensor dengan output 4-20mA ke U12 HOBO, UX120, atau ZW seri eksternal-saluran data

12-bit 4-20mA Masukan

Rayastock

Rp 4.269.937

12-bit 4-20 mA Masukan Adapter antarmuka dengan sensor memberikan sinyal 4-20 mA untuk terhubung ke sensor cerdas penebang data yang kompatibel. fitur adaptor ini baik

50 AMP Mini Split-inti

Rayastock

Rp 3.366.705

Kecil ukuran 50 AMP split-inti AC Current Transformer (CT) dipasang di sekitar kawat berarus untuk mengukur ampere AC. CT ini menyediakan 0-,333 Volt AC

75 AMP Mini Split-inti

Rayastock

Rp 3.366.705

Kecil ukuran 75 AMP split-inti AC Current Transformer (CT) dipasang di sekitar kawat berarus untuk mengukur ampere AC. CT ini menyediakan 0-,333 Volt AC

5 AMP Mini Split-inti AC

Rayastock

Rp 3.366.705

Kecil ukuran 5 AMP split-inti AC Current Transformer (CT) dipasang di sekitar kawat berarus untuk mengukur ampere AC. CT ini memberikan output

600 AMP Split-inti AC

Rayastock

Rp 3.726.404

The Magnelab AC Current 600 Amp AC Current Transformer atau CT (Magnelab bagian # SCT-2000-600) dipasang di sekitar membawa kawat saat ini untuk mengukur AC

100 AMP Split-inti AC

Rayastock

Rp 2.978.777

Magnelab AC Current 100 Amp AC Current Transformer atau CT (Magnelab bagian # SCT-1250-100) dipasang di sekitar membawa kawat saat ini untuk

20-200 Amp split-inti AC

Rayastock

Rp 3.726.404

Sebuah split-inti AC saat sensor responsif selama rentang 20 sampai 200 ampli AC untuk digunakan dengan U12, data logger UX120, dan ZW dengan saluran input

10-100 Amp split-inti AC

Rayastock

Rp 5.242.648

Sebuah split-inti AC saat sensor responsif selama rentang 10 sampai 100 ampli AC untuk digunakan dengan U12, data logger UX120, dan ZW dengan saluran input

200 AMP Split-inti AC

Rayastock

Rp 4.200.457

Magnelab AC Current 200 Amp AC Current Transformer atau CT (Magnelab bagian # SCT-1250-200) dipasang di sekitar membawa kawat saat ini untuk

5-50 Amp split-inti AC

Rayastock

Rp 5.242.648

Sebuah split-inti AC saat sensor responsif selama rentang 5 sampai 50 amp AC untuk digunakan dengan U12, data logger UX120, dan ZW dengan saluran input

2-20 Amp split-inti AC

Rayastock

Rp 5.242.648

Sebuah split-inti AC saat sensor responsif selama rentang 2 sampai 20 amp AC untuk digunakan dengan U12, UX120 dan ZW penebang data dengan saluran input

HOBO 4-Channel Eksternal

Rayastock

Rp 10.097.421

Mempekerjakan beberapa energi dan sensor lingkungan, mulai dari ampli ke suhu , dengan data logger HOBO U12-008.Kandang cuaca yang memungkinkan U12-008 untuk

HOBO RX3000 Remote

Rayastock

Rp 17.905.543

HOBO RX3000 adalah stasiun logging Onset generasi berikutnya data remote yang menyediakan akses cepat ke data lingkungan spesifik di mana saja, kapan saja melalui

HOBO Plug Beban Data

Rayastock

Rp 5.579.264

Onset ini HOBO Plug Beban Data Logger adalah akurasi tinggi, mudah menyebarkan data yang logger yang mengukur dan mencatat kekuatan dan energi konsumsi beban 120V steker dari

0 ke 24 VoltsDC Voltage

Rayastock

Rp 2.352.307

CABLE-ADAP24 adalah kabel input eksternal memberikan masukan sensor analog dari 0-24 VDC max. untuk node HOBO ZW Seri

HOBO 4-Channel Analog

Rayastock

Rp 4.175.114

HOBO UX120-006M Analog Data Logger adalah kinerja tinggi, layar LCD data logger untuk membangun aplikasi monitoring kinerja. Sebagai Onset tertinggi akurasi data logger, ia

HOBO Micro USB Station

Rayastock

Rp 5.279.239

Ddidesain ulang HOBO Micro USB Station adalah data logger cuaca untuk monitoring multi-channel dari mikro. Stasiun bertenaga baterai ini menerima hingga lima plug-and-play Cerdas

HOBO H22 Energi Data

Rayastock

Rp 13.908.629

Membangun efisiensi energi yang lebih baik dan manajemen daya dengan E50B2 Power & Energi Meter. sensor hemat biaya ini sederhana untuk menyebarkan dan baik dapat

HOBO 4-Channel Pulse

Rayastock

Rp 12.209.594

HOBO UX120 Pulse Data Logger adalah sangat serbaguna, 4-channel energi data logger yang menggabungkan fungsionalitas dari empat penebang data yang terpisah ke dalam satu unit yang

HOBO 4-Channel Pulse

Rayastock

Rp 4.803.145

HOBO UX120 Pulse Data Logger adalah sangat serbaguna, 4-channel energi data logger yang menggabungkan fungsionalitas dari empat penebang data yang terpisah ke dalam satu unit yang

0-5 VoltsDC Voltage

Rayastock

Rp 1.351.379

Max. input: 0–5 VDC Accuracy with U12: ±4 mV ±2.7% of reading Accuracy with ZW: ±3.1 mV ±2.2% Accuracy with UX120-006M:

0-10 VoltsDC Voltage

Rayastock

Rp 2.352.307

Max. input: 0–10 VDC Accuracy with U12:±8 mV ±2.7% of reading Accuracy with ZW: ±6.2 mV ±2.2% Accuracy with UX120-006M:

150 Volt AC Potensi

Rayastock

Rp 5.200.960

Measurement range: 150, 300, 600 Volts AC Accuracy: ±1% (from 10% to 130% of rated voltage) Phase angle: Output signal to FlexSmart Module: 0.333 Volt at rated input

ConLab 0-300 Volt AC

Rayastock

Rp 8.328.014

Ranges: 0–300 volts RMS Sensor accuracy: < ±0.1% of span (20% to 120% of range) ±0.25% of span (10% of range) Over range: +20% of

0-2,5 VoltsDC Voltage

Rayastock

Rp 2.185.557

Input range: 0 to 2.5 VDC Accuracy w/U12: ±2 mV ±2.5% of absolute reading Accuracy w/UX120-006M: ±0.1 mV ±0.1% of absolute

300 Volt AC Potensi

Rayastock

Rp 5.200.960

Measurement range: 150, 300, 600 Volts AC Accuracy: ±1% (from 10% to 130% of rated voltage) Phase angle: <1 degree Output signal to FlexSmart Module: 0.333

12-bit Sensor Voltage

Rayastock

Rp 4.103.187

Measurement range: 0-5 V DC Accuracy: ±10mV ±0.3% of reading (over operating temperature range) Resolution: ±1.221 millivolts Input impedance:

600 Volt AC Potensi

Rayastock

Rp 5.200.960

Measurement range: 150, 300, 600 Volts AC Accuracy: ±1% (from 10% to 130% of rated voltage) Phase angle: <1 degree Output signal to FlexSmart Module: 0.333

ConLab 0-150 Volt AC

Rayastock

Rp 4.731.826

Ranges: 0–150 volts RMS Sensor accuracy: < ±0.1% of span (20% to 120% of range) ±0.25% of span (10% of range) Over range: +20% of

HOBO Bluetooth Low

Rayastock

Rp 4.064.686

Temperature Sensor Range                           

HOBO 4-Channel External

Rayastock

Call

Analog channels:0 to 2.5 Vdc (w/CABLE-2.5-STEREO); 0 to 5 Vdc (w/CABLE-ADAP5); 0 to 10 Vdc (w/ CABLE-ADAP10); 0 to 24 Vdc (w/CABLE-4-20MA) Accuracy (logger

Differential Air

Rayastock

Call

Media Compatibility Dry air or inert gas Input Power 12-30VDC, or 24VAC nominal Output Field-selectable: 2-wire, loop-powered 4-20mA (DC only, clipped and capped) or 3-wire

HOBO Dissolved Oxygen

Rayastock

Rp 24.631.366

Dissolved Oxygen   Sensor Type:Optical  Measurement Range:0 to 30 mg/L  Calibrated Range:0 to 20 mg/L; 0 to 35°C (32 to

HOBO

Rayastock

Rp 3.718.677

Measurement Range Temperature: -20° to 70°C (-4° to 158°F) RH: 5% to 95% RH Analog channels: 0 to 2.5 Vdc (w/CABLE-2.5-STEREO); 0 to 5 Vdc

0 to 2.5 VoltsDC Voltage

Rayastock

Call

  Input range: 0 to 2.5 VDC Accuracy w/U12: ±2 mV ±2.5% of absolute reading Accuracy w/UX120-006M: ±0.1 mV ±0.1% of

HOBO Bluetooth Low

Rayastock

Call

Pressure (Absolute) and Water Level Measurements MX2001-01-S and MX2001-01-Ti-S  -  9 Meter (30) range​ Operation Range : 0 to 207 kPa (0 to 30

HOBO MX2302 External

Rayastock

Rp 5.111.388

Temperature Sensor   RangeMX2301 and MX2305 internal sensors: -40 to 70°C (-40 to 158°F) MX2302 external temperature sensor: -40 to 70°C (-40

HOBO 250-Foot Depth

Rayastock

Call

Pressure and Water Level Measurements U20-001-03 and U20-001-03-Ti Operation Range0 to 850 kPa (0 to 123.3 psia); approximately 0 to 76.5 m (0 to 251 ft) of water depth at sea

HOBO 30-Foot Depth Water

Rayastock

Call

Pressure and Water Level Measurements U20-001-01 and U20-001-01-Ti Operation Range0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or

HOBO Water Level (13 ft)

Rayastock

Rp 7.346.100

Pressure (Absolute) and Water Level Measurements U20L-04 Operation Range0 to 145 kPa (0 to 21 psia); approximately 0 to 4 m (0 to 13 ft) of water depth at sea level, or 0 to 7 m

HOBO Water Level (30 ft)

Rayastock

Rp 7.346.100

Pressure (Absolute) and Water Level Measurements U20L-01 Operation Range0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m

HOBO Water Level (100

Rayastock

Rp 7.346.100

Pressure (Absolute) and Water Level Measurements U20L-02 Operation Range0 to 400 kPa (0 to 58 psia); approximately 0 to 30.6 m (0 to 100 ft) of water depth at sea level, or 0 to

HOBO 100-Foot Depth

Rayastock

Rp 14.273.969

Pressure and Water Level Measurements U20-001-02 and U20-001-02-Ti Operation Range0 to 400 kPa (0 to 58 psia); approximately 0 to 30.6 m (0 to 100 ft) of water depth at sea

HOBO 13-Foot Depth

Rayastock

Rp 11.983.733

Pressure and Water Level Measurements U20-001-04 and U20-001-04-Ti Operation Range0 to 145 kPa (0 to 21 psia); approximately 0 to 4 m (0 to 13 ft) of water depth at sea level, or

HOBO 13-Foot Fresh Water

Rayastock

Rp 10.273.067

Pressure and Water Level Measurements U20-001-04 and U20-001-04-Ti Operation Range0 to 145 kPa (0 to 21 psia); approximately 0 to 4 m (0 to 13 ft) of water depth at sea level, or

HOBO 250-Foot Depth

Rayastock

Rp 14.273.969

Pressure and Water Level Measurements U20-001-03 and U20-001-03-Ti Operation Range0 to 850 kPa (0 to 123.3 psia); approximately 0 to 76.5 m (0 to 251 ft) of water depth at sea

HOBO 100-Foot Depth

Rayastock

Rp 10.273.067

Pressure and Water Level Measurements U20-001-02 and U20-001-02-Ti Operation Range0 to 400 kPa (0 to 58 psia); approximately 0 to 30.6 m (0 to 100 ft) of water depth at sea

HOBO 30-Foot Depth

Rayastock

Rp 11.983.733

Pressure and Water Level Measurements U20-001-01 and U20-001-01-Ti Operation Range0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or

HOBO Water Level Data

Rayastock

Rp 12.137.693

Pressure Sensor Operation range: 0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m

HOBO Water Level Data

Rayastock

Rp 22.698.313

Pressure Sensor Operation range: 0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m

HOBO Water Level Data

Rayastock

Rp 12.137.693

Pressure Sensor Operation range: 0 to 400 kPa (0 to 58 psia); approximately 0 to 30.6 m (0 to 100 ft) of water depth at sea level, or 0 to 33.6 m (0 to 111 ft) of water at 3,000

HOBO Water Level Data

Rayastock

Rp 22.698.313

Pressure Sensor Operation range: 0 to 400 kPa (0 to 58 psia); approximately 0 to 30.6 m (0 to 100 ft) of water depth at sea level, or 0 to 33.6 m (0 to 111 ft) of water at 3,000

HOBO Water Level Data

Rayastock

Rp 22.698.313

Pressure Sensor Operation range: 0 to 145 kPa (0 to 21 psia); approximately 0 to 4 m (0 to 13 ft) of water depth at sea level, or 0 to 7 m (0 to 23 ft) of water at 3,000 m

HOBO Water Level Data

Rayastock

Rp 12.137.693

Pressure Sensor Operation range: 0 to 145 kPa (0 to 21 psia); approximately 0 to 4 m (0 to 13 ft) of water depth at sea level, or 0 to 7 m (0 to 23 ft) of water at 3,000 m

Air Velocity (0.15 to 10

Rayastock

Call

Measurement range "O" model: 0.15 - 5 m/s (30 - 985 fpm) Measurement range "P" model: 0.15 - 10 m/s (30 - 1969 fpm) Accuracy: Greater of 10% of reading or

Air Velocity Sensor

Rayastock

Call

Measurement range "O" model: 0.15 - 5 m/s (30 - 985 fpm) Measurement range "P" model: 0.15 - 10 m/s (30 - 1969 fpm) Accuracy: Greater of 10% of reading or

Air Velocity (.15 to 5

Rayastock

Rp 10.687.575

Measurement range O model: 0.15 - 5 m/s (30 - 985 fpm) Measurement range P model: 0.15 - 10 m/s (30 - 1969 fpm) Accuracy: Greater of 10% of reading or +/-0.05 m/s or 1%

Air Velocity (0.15 to 5

Rayastock

Rp 7.564.740

Measurement range O model: 0.15 - 5 m/s (30 - 985 fpm) Measurement range P model: 0.15 - 10 m/s (30 - 1969 fpm) Accuracy: Greater of 10% of reading or +/-0.05 m/s or 1%

HOBO H22 Energy Data

Rayastock

Rp 7.553.109

Operating range: -20° to 50°C (-4° to 122°F) with alkaline batteries -40° to 60°C (-40° to 140°F) with lithium

HOBO Four Analog Port

Rayastock

Rp 5.924.229

Buffer memory: 3k measurements Sample rate: 1 min to 18 hrs Transmission rate: 2 min and greater Power options: AC power adapter, battery backup Measurement range analog

EG4115 Core - 15 Input

Rayastock

Call

Measurement AC Voltage:L1: 85-277 Vrms L2: 0-277 Vrms L3: 0-277 Vrms DC Voltage:42 Vrms Power: 9-60 Vdc Measurement: +/-60 Vdc Current:15 channels 5-6900A max per

EG4130 Pro - 30 Input

Rayastock

Call

Measurement AC Voltage:L1: 85-277 Vrms L2: 0-277 Vrms L3: 0-277 Vrms DC Voltage:42 Vrms Power: 9-60 Vdc Measurement: +/-60 Vdc Current:30 channels 5-6900A max per

EG4100 Series Current

Rayastock

Call

Model A  B  C D  EOpening T-EG-0390-XXXX1.59”0.91”0.93”1.05”0.57”

HOBO Plug Load Data

Rayastock

Rp 5.579.264

RMS Voltage Accuracy:0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle RMS Current Accuracy:0.5% up to 14 Amp continuous;

E50B2 Power & Energy

Rayastock

Rp 13.908.629

Measurement Accuracy:     Real Power and Energy:IEC 62053-22 Class 0.5S, ANSI C12.20 0.5%    Reactive Power and Energy:IEC 62053-23

Smart Barometric

Rayastock

Rp 6.061.415

Measurement range: 660 to 1070 mbar (19.47 to 31.55 in. Hg) Accuracy: ±3.0 mbar (0.088 in. Hg) over full pressure range at 25°C (77°F); maximum error

HWS Barometric Pressure

Rayastock

Call

Measurement parameters: average over logging interval, user-defined sampling interval from 1 second Measurement range: 660 mb to 1070 mb (19.47 to 31.55 in. Hg) Operating

HOBO Bluetooth Low

Rayastock

Rp 11.587.856

Temperature Sensor Range : 0° to 50°C (32° to 122°F) Accuracy : ±0.21°C from 0° to 50°C

Telaire 7001 CO2 Sensor

Rayastock

Rp 13.540.713

Measurement Range  When using the CABLE-CO2 and a U12 or ZW: 0 to 2500 ppm When using the CABLE-2070 and a H22 or U30: 0 to 4000 ppm    Telaire 7001

Compressed Air Flow

Rayastock

Rp 14.747.326

Measurement range, 5200 model: 1 - 80 SCFM Measurement range, 5400 model: 16-200 SCFM (calibrated), 350 - 600 (uncalibrated) Accuracy: (5200 model) 5% of reading plus 1% of full

Compressed Air Flow

Rayastock

Rp 16.002.856

Measurement range, 5200 model: 1 - 80 SCFM Measurement range, 5400 model: 40-600 SCFM (calibrated), 350 - 600 (uncalibrated) Accuracy: (5200 model) 5% of reading plus 1% of full

HOBO Salt Water

Rayastock

Rp 15.356.651

Measurements: Actual Conductivity, Temperature, Specific Conductance at 25C (calculated), Salinity (calculated using PSS-78, the Practical Salinity Scale

HOBO Fresh Water

Rayastock

Rp 15.356.651

Memory: 18,500 temperature and conductivity measurements when using one conductivity range; 14,400 sets of measurements when using both conductivity ranges (64kbytes) Sample

Split-Core Bi-Polar DC

Rayastock

Rp 8.819.320

DC Amperage (bi-polar) Measurement range: +/- 2 to +/- 200 (via span adjust) Accuracy (below 100A span): +/- .5 A Accuracy (above 100A span): +/- .5% full scale Sensor

HOBO Extended Memory

Rayastock

Rp 3.866.447

Internal Sensor   Maximum state, event, runtime frequency: 1 Hz Preferred switch state: No magnet present (normally open)     External

HOBO State Data Logger

Rayastock

Rp 4.600.000

Internal Sensor   Maximum state, event, runtime frequency: 1 Hz Preferred switch state: No magnet present (normally open)       External

HOBO Pendant® Event

Rayastock

Rp 3.463.302

External Event Input Event sensor: Two-wire interface suitable for measuring mechanical and electrical contact closures Maximum input frequency: 1 Hz (1 pulse per

Ashcroft (200-psig)

Rayastock

Call

Measurement ranges: 100, 200, 500 psig Compensated temp range: -40° to 125°C (-40° to 257°F) Accuracy: ±1% FS from -20° to

Ashcroft (500-psig)

Rayastock

Call

Measurement ranges: 100, 200, 500 psig Compensated temp range: -40° to 125°C (-40° to 257°F) Accuracy: ±1% FS from -20° to

Ashcroft (100-psig)

Rayastock

Call

Measurement ranges: 100, 200, 500 psig Compensated temp range: -40° to 125°C (-40° to 257°F) Accuracy: ±1% FS from -20° to

WattNode 208-240VAC 2 or

Rayastock

Rp 7.094.985

Wye configuration ranges: 120, 208, 240 Volts AC - Neutral required    1 Phase 2 Wire 120V (with neutral)    1 Phase 3 Wire

WattNode 208/240 VAC

Rayastock

Rp 7.528.772

Operating: voltage range: ±20% of nominal Frequency: 60 Hz CT input: 0-0.5 VAC operating, 3 VAC maximum Connectors: UL, CSA recognized, detachable screw terminals

WattNode 480 VAC 3-phase

Rayastock

Call

Operating: voltage range: ±20% of nominal Frequency: 60 Hz CT input: 0-0.5 VAC operating, 3 VAC maximum Connectors: UL, CSA recognized, detachable screw terminals

Veris Kilowatt Hour

Rayastock

Rp 14.737.644

Frequency: 50 to 60Hz Accuracy: ±1% (3-phase model conforms to ANSI C12.1 metering standards) CT range: 0-300 Amp (T-VER-8051-300); 0-800 Amp

Veris 480 V, 100 Amp

Rayastock

Rp 19.685.951

Includes: 3 100 Amp Split-Core Current Transformers (CT) Input primary voltage: 480 Volts AC rms Accuracy: ±1% per ANSI (C12.1) (from 10 to 100% of CT rating) Number

Veris Kilowatt Hour

Rayastock

Rp 18.728.483

Frequency: 50 to 60Hz Accuracy: ±1% (3-phase model conforms to ANSI C12.1 metering standards) CT range: 0-300 Amp (T-VER-8051-300); 0-800 Amp

WattNode 208/240 VAC

Rayastock

Rp 6.661.199

Operating: voltage range: ±20% of nominal Frequency: 60 Hz CT input: 0-0.5 VAC operating, 3 VAC maximum Connectors: UL, CSA recognized, detachable screw terminals

HOBO RX3000 Remote

Rayastock

Call

Part Numbers: RX3003-SYS-KIT-806 and RX3003-SYS-KIT-808   HOBO RX3000 Cellular Data Logger 5W Solar Panel - SOLAR-5W Temperature/RH Smart Sensor with 2-meter cable -

Leaf Wetness Smart

Rayastock

Rp 4.055.077

Measurement range: 0 (dry) to 100% (wet) Operating range: -40°C to 70°C, (-40°F to 158°F) Repeatablility: ± 5% Resolution:

HOBO Light On/Off Data

Rayastock

Call

Light threshold: > 65 lux Light type: LED, CFL, fluorescent, HID, incandescent, natural UX90-002- Temperature Specification ChartTime accuracy: ±1 minute per

HOBO Occupancy/Light

Rayastock

Rp 6.500.000

Occupancy Sensor   Detection Range UX90-005x: maximum 5 m (15.4 ft); UX90-006x: maximum 12 m (39.4 ft)   Detection Performance UX90-005x: 94°

HOBO Occupancy/Light (5m

Rayastock

Rp 8.100.000

Detection range: UX90-005x: maximum 5 m (16.4 ft)   Detection Performance UX90-005x: 94° (±47°) Horizontal; 82°

HOBO Extended Memory

Rayastock

Call

Light threshold: > 65 lux Light type: LED, CFL, fluorescent, HID, incandescent, natural UX90-002- Temperature Specification ChartTime accuracy: ±1 minute per

HOBO Extended Memory

Rayastock

Call

Occupancy Sensor   Detection Range UX90-005x: maximum 5 m (16.4 ft); UX90-006x: maximum 12 m (39.4 ft)   Detection Performance UX90-005x: 94°

HOBO Extended Memory

Rayastock

Call

Occupancy Sensor   Detection Range UX90-005x: maximum 5 m (15.4 ft); UX90-006x: maximum 12 m (39.4 ft)   Detection Performance UX90-005x: 94°

HOBO Motor On/Off Data

Rayastock

Rp 3.361.433

Internal Motor Sensor   AC magnetic field threshold: > 40 mGauss at 60 Hz     External Input   External contact input: Electronic

HOBO Extended Memory

Rayastock

Call

Internal Motor Sensor   AC magnetic field threshold: > 40 mGauss at 60 Hz         External Input   External

Photosynthetic Light

Rayastock

Rp 5.279.239

Measurement parameters: average over logging interval, user-defined sampling interval from 1 second Measurement range: 0 to 2500 umol/m2/sec, wavelengths of 400 to 700

Electronic Switch Pulse

Rayastock

Rp 2.401.672

Maximum input frequency: 120 Hz (120 pulses per second) Measurement range: 0 – 65,533 pulses per logging interval Resolution: 1 pulse Lockout time: 45 µs

Contact Closure Pulse

Rayastock

Call

Maximum input frequency: 2 Hz (2 pulses per second) Measurement range: 0 – 65,533 pulses per logging interval Resolution: 1 pulse Lockout time: 327 ms ±

Contact Closure Pulse

Rayastock

Call

Maximum input frequency: 2 Hz (2 pulses per second) Measurement range: 0 – 65,533 pulses per logging interval Resolution: 1 pulse Lockout time: 327 ms ±

Electronic Switch Pulse

Rayastock

Call

Maximum input frequency: 120 Hz (120 pulses per second)Measurement range: 0 – 65,533 pulses per logging intervalResolution: 1 pulseLockout

Davis® 0.2 mm Rain

Rayastock

Rp 7.982.623

Measurement Range : 0 to 10.2 cm (0 to 4 in.) per hour, maximum 4,000 tips per logging interval Accuracy : ±4.0%, ±1 rainfall count between 0.2 and

Davis® 0.01"

Rayastock

Call

Measurement Range : 0 to 10.2 cm (0 to 4 in.) per hour, maximum 4,000 tips per logging interval Accuracy : ±4.0%, ±1 rainfall count

0.01" Rain Gauge

Rayastock

Rp 9.598.900

Measurement range: 0–10 cm or 0–5 in. per hour; maximum 4000 tips per interval Operating range: 0° to 50°C (32° to 122°F);

0.2 mm Rainfall (2m

Rayastock

Rp 11.165.859

Measurement range: 0–12.7 cm or 0–5 in. per hour; maximum 4000 tips per interval Operating range: 0° to 50°C (32° to 122°F);

HOBO Rain Gauge Data

Rayastock

Rp 10.095.421

Rain Gauge Maximum rainfall rate: 12.7 cm (5 in.) per hour Calibration accuracy: ±1.0% (up to 1 in./hour for the RG3 or 20 mm/hour for the RG3-M) Resolution: 0.01

HOBO MX2301

Rayastock

Rp 4.561.901

Temperature Sensor Range MX2301 and MX2305 internal sensors: -40 to 70°C (-40 to 158°F) MX2302 external temperature sensor: -40 to 70°C (-40 to

HOBO External Temp/RH

Rayastock

Rp 4.947.841

Temperature Sensor   Range: -20° to 70°C (-4° to 158°F) Accuracy: ±0.21°C from 0° to 50°C

HOBO

Rayastock

Rp 3.317.705

Temperature Sensor Range: -20° to 70°C (-4° to 158°F) Accuracy: ±0.21°C from 0° to 50°C

HOBO Temp/RH 2.5% Data

Rayastock

Rp 3.935.039

Temperature Sensor   Range: -20° to 70°C (-4° to 158°F) Accuracy: ±0.21°C from 0° to 50°C

HOBO Wireless

Rayastock

Rp 35.974.526

ZW-003 Temperature/Relative Humidity (RH) Data Node Specifications: Buffer memory: approx. 4k measurements Sample rate: 1 min to 18 hrs Transmission rate: 2 min and

HOBO External

Rayastock

Rp 4.898.777

Environmental   Operating temperature range -20°C to +50°C, (-4°F to +122°F) , 0 to 100% RH non-condensing Operating relative humidity

HOBO LCD -

Rayastock

Rp 5.437.147

Environmental   Operating temperature range -20°C to +50°C, (-4°F to +122°F) , 0 to 100% RH non-condensing Operating relative humidity

12-bit

Rayastock

Rp 5.032.524

Measurement Range Temp: -40°C to 75°C (-40°F to 167°F) RH: 0-100% RH at -40° to 75°C (-40° to 167°F); exposure to

HOBO U23 Pro v2 External

Rayastock

Rp 4.947.633

Temperature Sensor Operation range internal sensors: -40° to 70°C (-40° to 158°F) U23-002 external temperature sensor: -40° to

12-bit

Rayastock

Rp 5.605.856

Measurement Range Temp: -40°C to 75°C (-40°F to 167°F) RH: 0-100% RH at -40° to 75°C (-40° to 167°F); exposure to

HOBO U23 Pro v2

Rayastock

Rp 4.489.701

Temperature Sensor Operation range internal sensors: -40° to 70°C (-40° to 158°F) U23-002 external temperature sensor: -40° to

10HS Soil Moisture Smart

Rayastock

Rp 4.731.826

Measurement range in soil: 0 to 0.570 m³/m³ (volumetric water content) Accuracy: ±0.033 m³/m³ (±3.3%) typical 0 to

EC5 Soil Moisture Smart

Rayastock

Rp 4.731.826

Measurement Range In soil: 0 to 0.550(m³/m³) Extended range: -0.401 to 2.574 m³/m³ (full scale)   Accuracy: ±0.031

HOBO Pendant® MX

Rayastock

Rp 2.887.666

Temperature Sensor (MX2201 and MX2202)   Range : -20° to 70°C (-4° to 158°F) in air  -20° to 50°C

Solar Radiation (Silicon

Rayastock

Rp 5.392.636

Measurement range: 0 to 1280 W/m2 Operating temperature range: -40° to 75°C (-40° to 167°F) Accuracy: ±10 W/m2 or ±5%,

HOBO Pendant®

Rayastock

Rp 2.547.438

Measurement Range Temperature: -20° to 70°C (-4° to 158°F) Light: 0 to 320,000 lux (0 to 30,000 lumens/ft2)   Accuracy Temperature:

HOBO Pendant®

Rayastock

Rp 2.815.880

Measurement Range Temperature: -20° to 70°C (-4° to 158°F) Light: 0 to 320,000 lux (0 to 30,000 lumens/ft2)   Accuracy Temperature:

HOBO Pendant® MX

Rayastock

Rp 2.639.017

Temperature Sensor (MX2201 and MX2202)   Range : -20° to 70°C (-4° to 158°F) in air  -20° to 50°C

HOBO 4-Channel

Rayastock

Rp 6.354.346

J-210° to 760°C (-346° to 1,400°F)±0.6°C (±1.08°F) ± thermocouple probe accuracy0.03°C

HOBO Type J, K, T, E, R,

Rayastock

Rp 4.130.105

J-210° to 760°C (-346° to 1,400°F)±0.6°C (±1.08°F) ± thermocouple probe accuracy0.03°C

HOBO Temperature Data

Rayastock

Call

Range : -30° to 70°C (-22° to 158°F)   Accuracy : ±1.0°C from -30° to -5°C

HOBO

Rayastock

Call

Buffer memory: approx. 4k measurements Sample rate: 1 min to 18 hrs Transmission rate: 2 min and greater Power options: AC power adapter, battery

HOBO 64K Pendant®

Rayastock

Rp 2.821.728

Measurement range: -20° to 70°C (-4° to 158°F) Alarms: High and low alarms can be configured for total amount of contiguous or non-contiguous time

HOBO 8K Pendant®

Rayastock

Call

Alarms: High and low alarms can be configured for total amount of contiguous or non-contiguous time outside of user-defined limits between -20° and 70°C

HOBO 5-Inch Probe

Rayastock

Rp 7.695.226

Measurement range: -40° to 125°C (-40° to 257°F) Accuracy: ± 0.25°C from 0° to 50°C (±

HOBO Stainless

Rayastock

Rp 6.305.282

Measurement range: -40° to 125°C (-40° to 257°F) Accuracy: ± 0.25°C from 0° to 50°C (±

HOBO MX2303 Two External

Rayastock

Rp 4.647.609

Temperature Sensor   Range : MX2301 and MX2305 internal sensors: -40 to 70°C (-40 to 158°F) MX2302 external temperature sensor: -40 to 70°C

HOBO Water Temperature

Rayastock

Rp 4.003.632

Operation range†: -40° to 70°C (-40° to 158°F) in air; maximum sustained temperature of 50°C (122°F) in water Accuracy:

HOBO MX2304 External

Rayastock

Rp 4.094.932

XTemperature Sensor   Range : MX2301 and MX2305 internal sensors: -40 to 70°C (-40 to 158°F) MX2302 external temperature sensor: -40 to 70°C

HOBO MX2305 Temperature

Rayastock

Rp 3.677.817

Temperature Sensor   Range : MX2301 and MX2305 internal sensors: -40 to 70°C (-40 to 158°F) MX2302 external temperature sensor: -40 to 70°C

TidbiT v2 Water

Rayastock

Rp 3.905.443

Temperature Sensor :  Operation range:* -20° to 70°C (-4° to 158°F) in air; maximum sustained temperature of 30°C (86°F)

Type K 100 ft 24 AWG

Rayastock

Rp 3.143.370

Range: 0 to 285°C (32° to 545°F) 285 to 482°C (545° to 900°F) Accuracy: +/- 0.75%*°C (+/- 4°C) +/- 2.2°C

HOBO Deep Ocean

Rayastock

Rp 16.194.877

Measurement Range:-40° to 125°C (-40° to 257°F) Accuracy:±0.22°C at 25°C (±0.4°F at 77°F),

InTemp VFC Bluetooth Low

Rayastock

Call

Radio Power : 1 mW (0 dBm)   Transmission Range : Approximately 30.5 m (100 ft) line-of-sight   Wireless Data Standard : Bluetooth Low Energy (Bluetooth

InTemp Bluetooth Low

Rayastock

Call

Radio Power : 1 mW (0 dBm)   Transmission Range : Approximately 30.5 m (100 ft) line-of-sight   Wireless Data Standard : Bluetooth Low Energy (Bluetooth

InTemp Bluetooth Low

Rayastock

Call

Radio Power : 1 mW (0 dBm)   Transmission Range : Approximately 30.5 m (100 ft) line-of-sight   Wireless Data Standard : Bluetooth Low Energy (Bluetooth

InTemp Bluetooth Low

Rayastock

Rp 5.192.573

Radio Power : 1 mW (0 dBm)   Transmission Range : Approximately 30.5 m (100 ft) line-of-sight   Wireless Data Standard : Bluetooth Low Energy (Bluetooth

InTemp Bluetooth Low

Rayastock

Call

Logger Operating Range : -10° to 70°C (-14° to 158°F)   Radio Power : 1 mW (0 dBm)   Transmission Range : Approximately

InTemp Bluetooth Low

Rayastock

Call

Logger Operating Range : -30° to 70°C (-22° to 158°F)    Radio Power : 1 mW (0 dBm)   Transmission Range

InTemp Bluetooth Low

Rayastock

Call

Logger Operating Range :  -30° to 70°C (-22° to 158°F)    Radio Power : 1 mW (0 dBm)   Transmission Range

InTemp Dry Ice Logger -

Rayastock

Call

Sensor Range : -95° to 50°C (-139° to 122°F) Accuracy : ±1.5°C from -95° to -40°C (±2.7°F

InTemp Dry Ice Logger -

Rayastock

Rp 4.911.115

Sensor Range : -95° to 50°C (-139° to 122°F) Accuracy :  ±1.5°C from -95° to -40°C

InTemp Cryogenic Logger

Rayastock

Call

Sensor Range : -200° to 50°C (-328° to 122°F); To ensure insulation integrity, avoid flexing the wire during exposure to temperatures below

InTemp Cryogenic

Rayastock

Call

Sensor Range : -200° to 50°C (-328° to 122°F); To ensure insulation integrity, avoid flexing the wire during exposure to temperatures below

InTemp CX Gateway

Rayastock

Call

Transmission Range : Approximately 30.5 m (100 ft) line-of-sight   Wireless Data Standard : Bluetooth 4.2 (BLE)   Connectivity : WiFi 802.11a/b/g/n 2.4/5 GHz

HOBO Pendant® G Data

Rayastock

Rp 3.214.241

Measurement Range: ± 3 g; 29.4 m/s² (96.5 ft/s²) Accuracy: ± 0.075 g; 0.735 m/s² (2.41 ft/s²) at 25°C

Volatile Organic

Rayastock

Call

Measurement range:  selectable 0 - 10, 0 - 100, 0 - 1000 ppm (parts per million) Accuracy:  (0-10 and 0-100 ppm)  +/- 2%; (100-1000 ppm) +/-

No-lead Water Flow Meter

Rayastock

Rp 6.184.033

Measurement range:  .25 to 22.0 Accuracy:  AWWA spec 97 - 103% Connection size:  ANSI/ASME B1.20.1-1983; 1-11.5 SNPSM thread; 5/8 x 3/4 in

Stevens SDX Real Time

Rayastock

Call

Power requirements : 9 - 30 VDC   Output : 4-20 mA current signal, linearly corresponding to range   Operating temperature : -40° F to

12-Bit Temperature (17 m

Rayastock

Call

Measurement range: -40° to 100°C (-40° to 212°F) sensor tip* Accuracy: < ± 0.2°C from 0° to 50°C

Davis® Wind Speed

Rayastock

Rp 10.446.396

Operating Temperature Range : -40°C to 65°C (-40°F to 149°F)   Environmental Rating : Weatherproof Housing

Wind Speed and Direction

Rayastock

Rp 17.056.920

Masukkan keterangan produk

Wind Direction Smart

Rayastock

Rp 9.895.679

Measurement Range :0 to 355 degrees, 5 degree dead band Maximum Wind Speed Survival: 67 m/sec (150 mph) Accuracy :± 5 degrees Resolution : 1.4 degrees Starting

RM Young Wind Monitor

Rayastock

Rp 58.000.000

Masukkan keterangan produk

RM Young AQ Wind Monitor

Rayastock

Rp 50.750.000

Masukkan keterangan produk

Type J Subminiature

Rayastock

Rp 1.327.713

Masukkan keterangan produk

Type K 6 ft Beaded

Rayastock

Rp 2.271.119

Range: 0 to 285°C (32° to 545°F) 285 to 482°C (545° to 900°F) Accuracy: +/- 0.75%*°C (+/- 4°F) +/-

Type J 100 ft

Rayastock

Rp 3.143.370

Range: 0 to 250°C (32° to 482°F) Initial accuracy: +/- 2.2.0°C (+/- °F)  ±data logger accuracy Insulation: Type J

HOBO TidbiT MX

Rayastock

Rp 4.048.027

Temperature Sensor (MX2203 and MX2204)   Range : MX2203: -20° to 70°C (-4° to 158°F) in air; -20° to 50°C (-4°

HOBO Pendant® MX

Rayastock

Rp 2.887.666

Temperature Sensor (MX2201 and MX2202)   Range : -20° to 70°C (-4° to 158°F) in air  -20° to 50°C

HOBO TidbiT MX

Rayastock

Rp 3.882.261

Temperature Sensor (MX2203) Range : MX2203: -20° to 70°C (-4° to 158°F) in air; -20° to 50°C (-4° to 122°F) in

Temperature (6) Sensor

Rayastock

Rp 1.745.787

Measurement range: -40° to 100°C (-40° to 212°F) Accuracy: w/U12: ±0.25°C from 0° to 50°C

Air/Water/Soil

Rayastock

Call

Measurement range: -40° to 50°C (-40° to 122°F) in water; -40° to 100°C (-40° to 212°F) in air Accuracy: w/U12:

Stainless Steel

Rayastock

Rp 2.568.900

Measurement range: -40° to 100°C (-40° to 212°F) Accuracy: w/U12: ±0.25°C from 0° to 50°C

Air/Water/Soil

Rayastock

Call

Measurement range: -40° to 50°C (-40° to 122°F) in water; -40° to 100°C (-40° to 212°F) in air Accuracy: w/U12:

pHionics STs pH

Rayastock

Call

Masukkan keterangan produk

HOBO Rain Gauge (Metric)

Rayastock

Call

Rain Gauge Maximum rainfall rate: 12.7 cm (5 in.) per hour Calibration accuracy: ±1.0% (up to 1 in./hour for the RG3 or 20 mm/hour for the RG3-M) Resolution: 0.01

Temperature (6) Sensor

Rayastock

Call

Measurement range: -40° to 100°C (-40° to 212°F) Accuracy: w/U12: ±0.25°C from 0° to 50°C

Air/Water/Soil

Rayastock

Call

Measurement range: -40° to 50°C (-40° to 122°F) in water; -40° to 100°C (-40° to 212°F) in air Accuracy: w/U12:

Showing 1 to 15 of 15 (1 Pages)